Stage 2 & 3 Air Filters. Wideband Air Fuel Ratio (AFR) Sensor Module with Bosch LSU4.9 Sensor. PLX Generation 4 with Bosch Wideband sen.. PLX Generation 4 with Bosch Wideband sensor LSU 4.9. We're proud to introduce our next generation wideband oxygen sensor controller with intelligent health monitoring technology and current for improved sensor performance. Our new Gen4 Wideband AFR utilizes the next generation in Bosch Wideband Air/Fuel Ratio sensor technology. The Gen4 is faster, more accurate, more durable, and uses less power than the Gen3. The Gen4 also employs the innovative PLX Devices new intelligent health monitoring technology where the oxygen sensor is meticulously monitored every 2mS (488 times per second) to obtain peak performance, accuracy and reaction time. Pair the SM/AFR with the updated patented DM-6 touch screen MultiGauge, battery voltage is displayed from 9V-20V, sensor life is displayed from 0-100%. The PLX Wideband AFR (UEGO) combines an accurate, fast response wideband AFR (Air Fuel Ratio) controller with a Bosch LSU4.9 wideband oxygen sensor. The wideband controller (SM-AFR) works with gasoline, bio diesel, ethanol, methanol, E85, LPG, and CNG. It includes two analog outputs (wideband 0-5V, and narrowband 0-1V) for interfacing with 3rd party devices and one digital serial output for interfacing with the DM-6 gauge and other Multi Gauges. The wideband analog output is ideal for interfacing with aftermarket ECU's and data loggers. The narrowband output is ideal for stock narrowband oxygen sensor replacement where the simulated narrowband analog output is fed back into your ECU to make it operate as if the stock narrowband oxygen sensor is still installed while running the PLX wideband setup. All three outputs can be used simultaneously. Additional features include advanced soft start technology which prolongs the oxygen sensor's life and an plastic enclosure for durability and reliability. Gen 3 VS Gen 4. Uses only 7.5Watts compared to 10Watts.

Less susceptible to contamination to surrounding pollution. 10 years of average service life. New Sensor: Bosch LSU 4.9.

New Sensor: O2 Sensor Health. New Sensor: O2 Sensor Reaction Time. 1 digital input, 1 digital output.

2 x 2.875 x 1.125 (52 x 75 x 28mm) L x W x H. PLX Critical Response Technology, Fast Response PID.

0 - 100 O2 Sensor Health 0 - 1000 mS Reaction Time 9 - 20 Volts. Wideband Linear 0-5V, Narrowband 0-1V (Driving Current 20mA). 20 Watts (Max), 13 Watts (Typical). High Efficiency Switching with Soft Start Technology. 0 - 85 Deg Celsius.

One Bosch LSU 4.9. Wideband 0-5V analog linear output. Narrowband (Gasoline) 0-1V analog output.

Bosch LSU 4.9 wideband sensor. 4ft power wire with 2.1mm connector.

4ft Analog wires and connector with 4 terminals. IMFD Stands for intelligent multi-functional display.

It is the PLX standard for connecting everything in a daisy-chain. Any product labeled with are fully compatible with each other.

Up to 32 sensor modules can be connected in any combination. To Display Modules or Data Logger. Up to 32 display modules can be connected in any combination.

From Sensor Modules or Data Logger Output. The simple setup connects to just one SM module. This is great for stand alone gauges. Looking at the above diagram. PLX Display Modules are also compatible with the PLX iMFD serial stream.

Two Options for datalogging are available. IMFD Data Logger and the iMFD Serial USB Adapter. IMFD Serial to USB Adapter. USB to PC High Speed download from flash Real-time. USB to PC Real-time only.

Please try the sensor before you install it. In case you found that the sensor does not work properly please contacy us as soon as possible. The sensor should never be installed the sensor on the exhaust without power supply in case the engine is running. The ideal distance of sensor installation from the downstream is just before the catalyst. If the installation position is no more 50cm from the downstream please use a special bung to remove heat.

If the engine is working with high EGT temperature (more than 800C) like the turbocharged engines. You should install the sensor at least 60cm away from the downstream and use a special bung to remove heat. To prevent collection of liquids between this sensor housing and sensor element during the cold start phase, the installation angle should be inclined at least 10 towards horizontal with the electrical connection upwards. If we anticipate a longer lead time, it will be noted in the item description. For customers that need their parts urgently we offer UPS and DHL Courier Service. UPS and DHL are using their global network to deliver on time for your needs the products ordered. This service is optional and it comes with an extra charge. Please note that, in this case, you will be accepting responsibility if anything were to happen to the package. Required by your country for importing consumer goods. In the event of a defect, these are your exclusive remedies.

Such benefits may include additional warranties or rights relating to the performance of this product and remedies applicable in the event of a defect. Thus, we offer the option to our customers to return even non defective products. Specifically, the item should not have been unpacked (apart from trying it of course), scratched, broken or painted. Also the item must have its original box.

The return of a non-defective product can only be done once. This credit balance can be used in any new order for the customer wishes. In case you want to cancel your order, please keep in mind that the cancellation will be accepted within 2 hour of the order completion. Beyond that point no cancellation will be accepted. Once we receive and inspect the product, we will credit your account.

Please allow 5-7 days for a credit to appear on your account. There is nothing to worry about. 10:00 - 19:00. 12 Gateway mews - N11 2UT - London - United Kingdom.

TPL IKE, is a Greek Company based in Patras established by a team of engineers whose sole goal was bringing high-quality shopping experience to any enthusiast who visits us online. Our team comprises of talented and committed engineers with wide technological expertise and experience in the motorsports industry. We hope our friendly and fair customer approach differentiates us from the competition out there. For us, the customer always comes first and we always do our best to make sure that each customer has an experience which is exemplary of our brand.

Our principles of offering top products, quality, service and rapid availability kept us going all these years. Ethnomartyron 40 - 26 333 - Patras - Greece. The item "PLX Devices Wideband Air Fuel Ratio (AFR) Sensor Module with Bosch LSU4.9" is in sale since Monday, July 9, 2018. The seller is "tpl-parts" and is located in Patras, Greece. This item can be shipped worldwide.
  • Country/Region of Manufacture: United States
  • Air & Fuel Sensor Type: Wideband Air Fuel Ratio (AFR)
  • Manufacturer Part Number: SMAFRG4